local timeUTC+1
Electricity · real time

Poland

delayed Electricity prices, interval by interval → Installed capacity →

Energy market

The price of electricity today

The day-ahead auction result, in Warsaw time.

Interval by interval

Grid snapshot

Demand, generation and balance, updated every minute.

delayed data · as of 30/10/2026, 22:30:00

National consumption
18,570MW
▲ +1,714 MW vs a day ago
Domestic production
18,469MW
101 MW below consumption. The real border balance is measured separately.
▲ +1,464 MW vs a day ago
Exporting now
488MW
Measured on the interconnectors: 2.6% of current production flows to neighbours.
▲ +185 MW vs a day ago
Solar production
0MW
unchanged vs a day ago
Day-ahead price
218.9EUR/MWh
CO₂ estimated
727g/kWhestimated

Physical cross-border flows

Electricity measured crossing every border in September 2026, valued at this zone's day-ahead price.

95.6% of the month's hours measured

Physical exports 1,281,985 MWh estimated market value 152,269,377 €, at 118.78 €/MWh
Physical imports 1,618,258 MWh estimated market value 283,332,753 €, at 175.09 €/MWh
Estimated market value −131,063,376 € the month averaged 149.93 €/MWh
Border with Out, MWh at €/MWh In, MWh at €/MWh Difference €
Germany 217,713 100.43 1,334,830 171.62 −207,222,762
Czechia 662,995 124.68 33,340 297.89 72,730,090
Slovakia 267,415 120.60 10,874 313.34 28,844,039
Ukraine 71,503 133.19 64,658 158.94 −752,812
Sweden 39,998 88.32 86,981 186.27 −12,669,587
Lithuania 22,360 108.92 87,574 164.75 −11,992,344

131,063,376 € for 336,273 MWh that stayed in the country works out at 389.75 € per megawatt-hour, in a month that averaged 149.93.

  • Energy that stayed, at the month's average price 50,416,993 38.5%
  • What came in arrived above that average 40,709,392 31.1%
  • What went out left below it 39,936,991 30.5%

The first line is energy the country needed and got. The other two — 80,646,383 € together — come not from how much moved but from when: cheap hours to sell in, expensive hours to buy in. That is the price of a timing mismatch, not a loss.

Official validation AWAITING OFFICIAL ANRE DATA

Physical cross-border flows and commercial electricity trades measure different phenomena. ANRE data is shown as an independent official benchmark and should not be interpreted as an exact reconciliation.

All months, every border

Not an invoice. Cross-border electricity is not sold country to country: the markets are coupled and the physical flow is the outcome of a shared auction. These figures value the measured flow at this zone's own day-ahead price, so both directions can be compared on the same scale.

Flows are measured, quarter-hour by quarter-hour; hourly borders are spread across the four quarters they cover, so every megawatt-hour meets the price that was actually in force. Energy entering the country is not the same as energy consumed here — some of it passes through.

Who we sold energy to

Who we sold energy to when they needed it — last 30 days

data for the last 30 days · 30 days covered

  • Czechia 834.57 GWh
    1,248 MW on average · 53.1%
  • Slovakia 334.82 GWh
    481 MW on average · 21.3%
  • Germany 188.93 GWh
    961 MW on average · 12.0%
  • Ukraine 142.41 GWh
    258 MW on average · 9.1%
  • Sweden 58.32 GWh
    212 MW on average · 3.7%
  • Lithuania 13.16 GWh
    104 MW on average · 0.8%

What we sent our neighbours, per border. Energy summed from quarter-hour averages over the days actually covered by the archive. The average power is over the hours in which it flowed this way, not over every hour. A country can appear in both lists: with the same neighbour we import in some hours and export in others.

Who we bought energy from

Who sold us energy when we needed it — last 30 days

data for the last 30 days · 30 days covered

  • Germany 1,780.50 GWh
    1,433 MW on average · 87.8%
  • Lithuania 106.50 GWh
    180 MW on average · 5.2%
  • Sweden 89.63 GWh
    267 MW on average · 4.4%
  • Ukraine 32.28 GWh
    199 MW on average · 1.6%
  • Czechia 18.06 GWh
    359 MW on average · 0.9%
  • Slovakia 1.99 GWh
    92 MW on average · 0.1%

What our neighbours sent us, per border. Energy summed from quarter-hour averages over the days actually covered by the archive. The average power is over the hours in which it flowed this way, not over every hour. A country can appear in both lists: with the same neighbour we import in some hours and export in others.

Energy sources

delayed data · as of 30/10/2026, 22:30:00

Hard coal
7,892MW
42.7% of total
Lignite
4,940MW
26.7% of total
Natural gas
2,543MW
13.8% of total
Onshore wind
1,855MW
10.0% of total
Other sources
615MW
3.3% of total
Biomass
279MW
1.5% of total
Oil
180MW
1.0% of total
Offshore wind
95MW
0.5% of total
Run-of-river hydro
55MW
0.3% of total
Hydro reservoir
16MW
0.1% of total
Pumped-storage hydro
0MW
0.0% of total
Solar
0MW
0.0% of total

Source shares

Every source, with its share and the emission factor used in the carbon estimate.

delayed data · as of 30/10/2026, 22:30:00

Hard coal: 7892 MW Lignite: 4940 MW Natural gas: 2543 MW Onshore wind: 1855 MW Other sources: 615 MW Biomass: 279 MW Oil: 180 MW Offshore wind: 95 MW 18,469 MW total
  • Hard coal 43% 7,892MW
    Renewable
    no
    Emission factor
    820 g CO₂eq/kWh
    Adds to the national average
    350.4 g/kWh
  • Lignite 27% 4,940MW
    Renewable
    no
    Emission factor
    1,054 g CO₂eq/kWh
    Adds to the national average
    281.9 g/kWh
  • Natural gas 14% 2,543MW
    Renewable
    no
    Emission factor
    490 g CO₂eq/kWh
    Adds to the national average
    67.5 g/kWh
  • Onshore wind 10% 1,855MW
    Renewable
    yes
    Emission factor
    11 g CO₂eq/kWh
    Adds to the national average
    1.1 g/kWh
  • Other sources 3% 615MW
    Renewable
    no
    Emission factor
    490 g CO₂eq/kWh · weak factor, the figure is fragile
    Adds to the national average
    16.3 g/kWh
  • Biomass 2% 279MW
    Renewable
    yes
    Emission factor
    230 g CO₂eq/kWh · weak factor, the figure is fragile
    Adds to the national average
    3.5 g/kWh
  • Oil 1% 180MW
    Renewable
    no
    Emission factor
    650 g CO₂eq/kWh
    Adds to the national average
    6.3 g/kWh
  • Offshore wind 1% 95MW
    Renewable
    yes
    Emission factor
    12 g CO₂eq/kWh
    Adds to the national average
    0.1 g/kWh
  • Run-of-river hydro 0% 55MW
    Renewable
    yes
    Emission factor
    24 g CO₂eq/kWh
    Adds to the national average
    0.1 g/kWh
  • Hydro reservoir 0% 16MW
    Renewable
    yes
    Emission factor
    24 g CO₂eq/kWh
    Adds to the national average
    0.0 g/kWh

Renewable energy

Share of clean sources in total production.

delayed data · as of 30/10/2026, 22:30:00

Onshore wind: 1855 MW · Biomass: 279 MW · Offshore wind: 95 MW · Run-of-river hydro: 55 MW · Hydro reservoir: 16 MW 12,5% of production
  • Onshore wind1,855 MW
  • Biomass279 MW
  • Offshore wind95 MW
  • Run-of-river hydro55 MW
  • Hydro reservoir16 MW

Energy radar

delayed data · as of 30/10/2026, 22:30:00

3.208 6.416 9.624 12.832 Solar: 0 MW Wind: 1950 MW Hydro: 71 MW Nuclear: 0 MW Gas: 2723 MW Coal: 12832 MW Solar Wind Hydro Nuclear Gas Coal

Czechia 1.130 MW export Germany 1.127 MW import Slovakia 441 MW export Sweden 436 MW import Ukraine 291 MW export Lithuania 190 MW export POLAND cross-border energy flows THE NATIONAL POWER SYSTEM IN ITS REGIONAL CONNECTIONS Import into Poland (energy coming in) Export from Poland (energy going out) Total cross-border exchange 3.613 MW Import 1.562 MW Export 2.051 MW 0 50 100 200 km N

The arrows and figures are measurements, as of 30 October at 22:00. The transmission grid is not shown: we do not have its routes for this country yet.

Exchanges with neighbours

Green = Poland exports, orange = Poland imports.

delayed data · as of 30/10/2026, 22:30:00

Czechia Czechia: 1130 MW Germany Germany: 1127 MW Slovakia Slovakia: 441 MW Sweden Sweden: 436 MW Ukraine Ukraine: 291 MW Lithuania Lithuania: 190 MW 0

The price right now, across Europe

The interval in progress, live data from right now, in every bidding zone we have a price for.

live data · as of 31/10/2026, 00:00:00

Poland is 35 of 46, counting from the dearest. Average across zones: 227 EUR/MWh.

  1. 1 IE 308EUR/MWh
  2. 2 AL 283EUR/MWh
  3. 2 XK 283EUR/MWh
  4. 4 ES 271EUR/MWh
  5. 5 PT 266EUR/MWh
  6. 5 MK 266EUR/MWh
  7. 7 ME 265EUR/MWh
  8. 8 RS 263EUR/MWh
  9. 8 IT (CALABRIA) 263EUR/MWh
  10. 8 IT (CENTRE_NORTH) 263EUR/MWh
  11. 8 IT (CENTRE_SOUTH) 263EUR/MWh
  12. 8 IT (NORTH) 263EUR/MWh
  13. 8 IT (SARDINIA) 263EUR/MWh
  14. 8 IT (SICILY) 263EUR/MWh
  15. 8 IT (SOUTH) 263EUR/MWh
  16. 16 AT 255EUR/MWh
  17. 16 BE 255EUR/MWh
  18. 16 BG 255EUR/MWh
  19. 16 CZ 255EUR/MWh
  20. 16 DE and LU 255EUR/MWh
  21. 16 DK (DK1) 255EUR/MWh
  22. 16 FR 255EUR/MWh
  23. 16 GR 255EUR/MWh
  24. 16 HR 255EUR/MWh
  25. 16 HU 255EUR/MWh
  26. 16 NL 255EUR/MWh
  27. 16 RO 255EUR/MWh
  28. 16 SI 255EUR/MWh
  29. 16 SK 255EUR/MWh
  30. 16 DK (DK2) 255EUR/MWh
  31. 31 CH 250EUR/MWh
  32. 32 SE (SE4) 247EUR/MWh
  33. 33 LT 230EUR/MWh
  34. 33 LV 230EUR/MWh
  35. 35 PL 219EUR/MWh
  36. 36 NO (NO2) 187EUR/MWh
  37. 37 SE (SE3) 182EUR/MWh
  38. 38 NO (NO1) 166EUR/MWh
  39. 39 NO (NO5) 160EUR/MWh
  40. 40 EE 143EUR/MWh
  41. 41 FI 128EUR/MWh
  42. 42 SE (SE2) 125EUR/MWh
  43. 43 NO (NO3) 107EUR/MWh
  44. 44 SE (SE1) 105EUR/MWh
  45. 45 TR 52EUR/MWh
  46. 46 NO (NO4) 24EUR/MWh

Wholesale prices for the interval covering this moment, bidding zone by bidding zone — countries with several zones appear once per zone, with its code in brackets. The average is arithmetic across zones, not weighted by demand: a small zone counts as much as a large one. The figures exclude network tariffs, excise duty and VAT.

What balancing cost, in the last 24 hours

The source for this country does not publish this dataset. Nothing is estimated in its place.

Who consumes: the base, the work rhythm, the day

An estimate from the shape of the consumption curve, not a measurement by customer category — that is not published in real time. Three parts: what never stops, what runs in shifts on working days, what switches on during the day.

archive up to 30/10/2026, 21:00:00

The base, non-stop
12,920MW
67.1% of the week's average · the Sunday-night floor: fridges, servers, installations that never stop
The work rhythm
2,128MW
11.0% of the week's average · how much more a working night carries than a Sunday night: the shifts
The day
4,214MW
21.9% of the week's average · what exceeds the working-night floor, on average: offices, shops, homes awake

Over the last seven days consumption averaged 19,262 MW and ranged between 13,407 and 23,154 MW.

How it was measured: the median of the 02–05 hours over 8 Sunday mornings (12,920 MW) and over 30 working mornings, Tuesday to Friday (15,047 MW), across the last 8 weeks; the average over the last seven days. The parts are cut from one another in order and add up exactly to the average.

The parts are shapes of the curve, not customer categories: the base holds every household's fridge as well as a plant that never stops; the day holds single-shift factories too. “Industrial” and “household” would be words these data cannot defend.

The operator's consumption forecast

How much the country is expected to consume, hour by hour, according to the forecast the transmission operator publishes for today and tomorrow. The line is the forecast; the bars, consumption measured so far.

forecast issued 30/10/2026, 23:44:14 · ENTSO-E

Operator's forecast Measured consumption, hourly average
0 12,500 25,000 37,500 50,000 today tomorrow now 00 06 12 18 00 06 12 18
Today's peak
20,250MW
at 17:00
Today's low
15,300MW
at 23:45
Next hour
16,500MW
at 00:15
Tomorrow's peak
—
Tomorrow's forecast is not published yet.

The forecast is the transmission operator's, published on its own platform — not a model of ours. It is revised during the day; for each hour the latest issue is shown. The running hour, in the bars, only shows what has accumulated so far.

Units out of service

Unavailable capacity, now and over the next two weeks

4,273 MW out now

Unit Lost Period
BełchatówLignite · Bełchatów B14 781 MW 13 Jul – 11 Dec forced
Kozienice 2Hard coal · Kozienice 2 B10 534 MW 18 Sept – 17 Dec forced
EC Żerań 2Natural gas · EC Żerań BGP 484 MW 12 May – 15 Dec maintenance
Pątnów 2Lignite · Pątnów 2 B9 441 MW 18 Sept – 31 Dec forced
Pątnów 2Lignite · Pątnów 2 B9 441 MW 27 Sept – 31 Dec forced
ŁagiszaHard coal · Łagisza B10 430 MW 29 Sept – 1 Nov forced
BełchatówLignite · Bełchatów B07 357 MW 13 Sept – 10 Dec forced
TurówLignite · Turów B04 236 MW 31 Jul – 15 Nov forced
PołaniecHard coal · Połaniec B7 221 MW 11 Oct – 12 Nov forced
Jaworzno 3Hard coal · Jaworzno 3 B6 211 MW 30 Sept – 28 Dec forced

and 1 more

How much prosumers produce right now

The source for this country does not publish this dataset. Nothing is estimated in its place.

Today, hour by hour

The source for this country does not publish this dataset. Nothing is estimated in its place.

How we estimated 727 g CO₂/kWh

This is an estimate, not a measurement. There is no official carbon-intensity measurement for this country, so we compute it from the production mix.

Σ(source generation × source factor) / Σ(generation), over positive values, with life-cycle factors.

The factors are life-cycle values — they include construction and fuel, not just combustion. That is why solar, wind and nuclear are not zero. Source: IPCC AR5 WG3, Anexa III, Tabelul A.III.2 (mediane), version 1.

SourceMWg/kWh
Hard coal7,892820
Lignite4,9401054
Natural gas2,543490
Onshore wind1,85511
Other sources615490
Biomass279230
Oil180650
Offshore wind9512
Run-of-river hydro5524
Hydro reservoir1624

Energy news

See all the news

No announcement has appeared yet. When the first one does, you will find it here.

The generation fleet, 2026

Installed capacity by source, as the operator reports it.

Installed capacity 68,256MW reported for 2026 Cleaner energy for tomorrow
Renewables 48.2% 32,923 MW
Largest source Solar 30.4%
Against 2025 +3,753 MW
Source Capacity (MW) Of total
Solar 20,734+2,918 30.4%
Hard coal 18,543−1 27.2%
Onshore wind 10,700+400 15.7%
Lignite 6,951 10.2%
Natural gas 5,930+119 8.7%
Other sources 1,980+242 2.9%
Pumped-storage hydro 1,525 2.2%
Biomass 698+62 1.0%
Hydro reservoir 468 0.7%
Oil 405+13 0.6%
Run-of-river hydro 323+1 0.5%
All the capacity statistics
How the renewable share is computed

Σ(renewable sources, positive values only) / Σ(all sources, positive only).

Numerator: Onshore wind, Biomass, Offshore wind, Run-of-river hydro, Hydro reservoir, Solar.

Denominator: 18,469 MW.

Pumped-storage hydro and waste are not counted as renewable — the first would double-count energy, the second is partly fossil and its biogenic fraction cannot honestly be separated.

Consumption — 90 days

24 hours 48 hours 7 days 30 days 90 days 1 year all
15,00020,000 08/0609/1710/28

84 points, P1D resolution. Long ranges are served from precomputed aggregates — a one-year chart from per-minute data would push hundreds of thousands of points into the browser for nothing. Our archive starts at 2015-01-01 00:00 UTC.

By source

Each source has its own page, with history and context:

Solar power · Wind power · Hydropower · Power from natural gas · Power from coal · Power from biomass

Alerts

Get a browser notification when something you care about happens. The rules are evaluated locally, on the live stream — they work as long as a tab with the site is open. Email alerts arrive together with accounts, in a later phase.

Put this data on your site

Copy the snippet below. The widget updates itself and loads no JavaScript into your page.

<iframe src="https://euroenergy.live/widgets/country/poland?lang=en" width="100%" height="380" style="border:1px solid #dbe1ec;border-radius:16px;max-width:400px" loading="lazy" title="Poland — Electricity in real time"></iframe>

View the widget · Download CSV

Source: ENTSO-E Transparency Platform · shares are computed on positive values, because solar farms draw from the grid at night · JSON API: /api/v1/countries/PL/latest

Solar calculatorWhat it costs, and how long until it pays for itself.Panels, panels with a battery, or just a battery if you already have panels. The calculator uses the solar radiation where you live, your household's consumption and local energy prices to estimate the cost, the yearly saving and the payback period.Open the page →