Iceland
This country has no bidding zone of its own, so it has no day-ahead price of its own.
Grid snapshot
Demand, generation and balance, updated every minute.
stale data · as of 17/10/2026, 23:00:00
Production mix
| Source | MW | Share |
|---|---|---|
| Hydro reservoir | 1,411 | 68.2% |
| Geothermal | 648 | 31.3% |
| Onshore wind | 10 | 0.5% |
| Oil | 0 | — |
| Neighbour | MW | Direction |
|---|---|---|
| no measured flows | ||
The source for this country does not publish this dataset. Nothing is estimated in its place.
The source for this country does not publish this dataset. Nothing is estimated in its place.
The arrows and figures are the last measurements the source published, from 17 October at 23:00. They are not the current exchanges. The transmission grid is not shown: we do not have its routes for this country yet.
The source for this country does not publish this dataset. Nothing is estimated in its place.
The price right now, across Europe
The interval in progress, live data from right now, in every bidding zone we have a price for.
live data · as of 19/10/2026, 08:30:00
Average across zones: 186 EUR/MWh.
-
1
IE 350EUR/MWh
-
2
CH 253EUR/MWh
-
2
RS 253EUR/MWh
-
4
IT (CENTRE_NORTH) 250EUR/MWh
-
4
IT (NORTH) 250EUR/MWh
-
6
AT 243EUR/MWh
-
7
SI 238EUR/MWh
-
8
HR 237EUR/MWh
-
9
BG 236EUR/MWh
-
9
RO 236EUR/MWh
-
9
HU 236EUR/MWh
-
12
SK 232EUR/MWh
-
13
CZ 229EUR/MWh
-
13
FR 229EUR/MWh
-
13
BE 229EUR/MWh
-
16
LT 226EUR/MWh
-
17
SE (SE4) 225EUR/MWh
-
18
DK (DK2) 224EUR/MWh
-
18
PT 224EUR/MWh
-
18
DE and LU 224EUR/MWh
-
18
DK (DK1) 224EUR/MWh
-
22
NL 223EUR/MWh
-
23
ME 221EUR/MWh
-
24
MK 210EUR/MWh
-
25
ES 197EUR/MWh
-
26
AL 187EUR/MWh
-
26
XK 187EUR/MWh
-
28
IT (CALABRIA) 186EUR/MWh
-
28
IT (CENTRE_SOUTH) 186EUR/MWh
-
28
IT (SICILY) 186EUR/MWh
-
28
IT (SOUTH) 186EUR/MWh
-
32
NO (NO2) 179EUR/MWh
-
33
NO (NO1) 169EUR/MWh
-
34
LV 168EUR/MWh
-
35
NO (NO5) 164EUR/MWh
-
36
GR 150EUR/MWh
-
37
SE (SE3) 147EUR/MWh
-
38
PL 128EUR/MWh
-
39
IT (SARDINIA) 127EUR/MWh
-
40
NO (NO3) 102EUR/MWh
-
41
SE (SE2) 35EUR/MWh
-
41
EE 35EUR/MWh
-
41
FI 35EUR/MWh
-
44
TR 34EUR/MWh
-
44
SE (SE1) 34EUR/MWh
-
46
NO (NO4) 21EUR/MWh
Wholesale prices for the interval covering this moment, bidding zone by bidding zone — countries with several zones appear once per zone, with its code in brackets. The average is arithmetic across zones, not weighted by demand: a small zone counts as much as a large one. The figures exclude network tariffs, excise duty and VAT.
The source for this country does not publish this dataset. Nothing is estimated in its place.
Who consumes: the base, the work rhythm, the day
An estimate from the shape of the consumption curve, not a measurement by customer category — that is not published in real time. Three parts: what never stops, what runs in shifts on working days, what switches on during the day.
archive up to 17/10/2026, 23:00:00
Over the last seven days consumption averaged 2,095 MW and ranged between 1,927 and 2,176 MW.
How it was measured: the median of the 02–05 hours over 7 Sunday mornings (1,960 MW) and over 30 working mornings, Tuesday to Friday (1,978 MW), across the last 8 weeks; the average over the last seven days. The parts are cut from one another in order and add up exactly to the average.
The parts are shapes of the curve, not customer categories: the base holds every household's fridge as well as a plant that never stops; the day holds single-shift factories too. “Industrial” and “household” would be words these data cannot defend.
The source for this country does not publish this dataset. Nothing is estimated in its place.
The source for this country does not publish this dataset. Nothing is estimated in its place.
The source for this country does not publish this dataset. Nothing is estimated in its place.
How we estimated 28 g CO₂/kWh
This is an estimate, not a measurement. There is no official carbon-intensity measurement for this country, so we compute it from the production mix.
Σ(source generation × source factor) / Σ(generation), over positive values, with life-cycle factors.
The factors are life-cycle values — they include construction and fuel, not just combustion. That is why solar, wind and nuclear are not zero. Source: IPCC AR5 WG3, Anexa III, Tabelul A.III.2 (mediane), version 1.
| Source | MW | g/kWh |
|---|---|---|
| Hydro reservoir | 1,411 | 24 |
| Geothermal | 648 | 38 |
| Onshore wind | 10 | 11 |
Energy news
See all the newsNo announcement has appeared yet. When the first one does, you will find it here.
The source for this country does not publish this dataset. Nothing is estimated in its place.
How the renewable share is computed
Σ(renewable sources, positive values only) / Σ(all sources, positive only).
Numerator: Hydro reservoir, Geothermal, Onshore wind.
Denominator: 2,069 MW.
Pumped-storage hydro and waste are not counted as renewable — the first would double-count energy, the second is partly fossil and its biogenic fraction cannot honestly be separated.
By source
Each source has its own page, with history and context:
Alerts
Get a browser notification when something you care about happens. The rules are evaluated locally, on the live stream — they work as long as a tab with the site is open. Email alerts arrive together with accounts, in a later phase.
Put this data on your site
Copy the snippet below. The widget updates itself and loads no JavaScript into your page.
<iframe src="https://euroenergy.live/widgets/country/iceland?lang=en" width="100%" height="380"
style="border:1px solid #dbe1ec;border-radius:16px;max-width:400px" loading="lazy"
title="Iceland — Electricity in real time"></iframe>
View the widget · Download CSV
Source: ENTSO-E Transparency Platform ·
shares are computed on positive values, because solar farms draw from the grid at night ·
JSON API: /api/v1/countries/IS/latest