local timeUTC+1
Electricity · real time

Poland

delayed Electricity prices, interval by interval → Installed capacity →

Energy market

The price of electricity today

The day-ahead auction result, in Warsaw time.

Interval by interval

Grid snapshot

Demand, generation and balance, updated every minute.

delayed data · as of 01/11/2026, 12:15:00

National consumption
16,228MW
▼ −3,214 MW vs a day ago
Domestic production
18,021MW
Covers all national consumption; the 1,793 MW surplus (11.1%) goes to export.
▼ −2,572 MW vs a day ago
Exporting now
1,439MW
Measured on the interconnectors: 8.0% of current production flows to neighbours.
▲ +999 MW vs a day ago
Solar production
3,784MW
21.0% of current production.
▲ +653 MW vs a day ago
Day-ahead price
112.2EUR/MWh
CO₂ estimated
627g/kWhestimated

Physical cross-border flows

Electricity measured crossing every border in October 2026, valued at this zone's day-ahead price.

Physical exports 1,628,879 MWh estimated market value 227,993,191 €, at 139.97 €/MWh
Physical imports 2,104,795 MWh estimated market value 396,051,674 €, at 188.17 €/MWh
Estimated market value −168,058,483 € the month averaged 169.24 €/MWh
Border with Out, MWh at €/MWh In, MWh at €/MWh Difference €
Germany 188,931 115.82 1,847,653 187.28 −324,149,034
Czechia 868,524 141.37 18,056 328.13 116,857,339
Slovakia 347,020 143.30 1,990 290.24 49,151,935
Ukraine 152,361 156.01 32,280 147.93 18,995,122
Sweden 58,710 135.51 94,822 206.49 −11,623,699
Lithuania 13,332 140.56 109,993 174.23 −17,290,146

168,058,483 € for 475,916 MWh that stayed in the country works out at 353.13 € per megawatt-hour, in a month that averaged 169.24.

  • Energy that stayed, at the month's average price 80,541,781 47.9%
  • What came in arrived above that average 39,845,927 23.7%
  • What went out left below it 47,670,775 28.4%

The first line is energy the country needed and got. The other two — 87,516,702 € together — come not from how much moved but from when: cheap hours to sell in, expensive hours to buy in. That is the price of a timing mismatch, not a loss.

Official validation AWAITING OFFICIAL ANRE DATA

Physical cross-border flows and commercial electricity trades measure different phenomena. ANRE data is shown as an independent official benchmark and should not be interpreted as an exact reconciliation.

All months, every border

Not an invoice. Cross-border electricity is not sold country to country: the markets are coupled and the physical flow is the outcome of a shared auction. These figures value the measured flow at this zone's own day-ahead price, so both directions can be compared on the same scale.

Flows are measured, quarter-hour by quarter-hour; hourly borders are spread across the four quarters they cover, so every megawatt-hour meets the price that was actually in force. Energy entering the country is not the same as energy consumed here — some of it passes through.

Who we sold energy to

Who we sold energy to when they needed it — last 30 days

data for the last 30 days · 30 days covered

  • Czechia 833.46 GWh
    1,245 MW on average · 55.7%
  • Slovakia 329.87 GWh
    474 MW on average · 22.0%
  • Ukraine 154.99 GWh
    268 MW on average · 10.4%
  • Germany 119.35 GWh
    878 MW on average · 8.0%
  • Sweden 46.15 GWh
    190 MW on average · 3.1%
  • Lithuania 12.91 GWh
    103 MW on average · 0.9%

What we sent our neighbours, per border. Energy summed from quarter-hour averages over the days actually covered by the archive. The average power is over the hours in which it flowed this way, not over every hour. A country can appear in both lists: with the same neighbour we import in some hours and export in others.

Who we bought energy from

Who sold us energy when we needed it — last 30 days

data for the last 30 days · 30 days covered

  • Germany 1,867.46 GWh
    1,434 MW on average · 88.2%
  • Lithuania 106.20 GWh
    179 MW on average · 5.0%
  • Sweden 98.79 GWh
    270 MW on average · 4.7%
  • Ukraine 23.69 GWh
    173 MW on average · 1.1%
  • Czechia 17.98 GWh
    361 MW on average · 0.8%
  • Slovakia 1.99 GWh
    92 MW on average · 0.1%

What our neighbours sent us, per border. Energy summed from quarter-hour averages over the days actually covered by the archive. The average power is over the hours in which it flowed this way, not over every hour. A country can appear in both lists: with the same neighbour we import in some hours and export in others.

Energy sources

delayed data · as of 01/11/2026, 12:15:00

Hard coal
7,310MW
40.6% of total
Solar
3,784MW
21.0% of total
Lignite
3,433MW
19.1% of total
Natural gas
2,150MW
11.9% of total
Other sources
560MW
3.1% of total
Biomass
341MW
1.9% of total
Onshore wind
164MW
0.9% of total
Oil
161MW
0.9% of total
Run-of-river hydro
56MW
0.3% of total
Offshore wind
45MW
0.3% of total
Hydro reservoir
17MW
0.1% of total
Pumped-storage hydro
0MW
0.0% of total

Source shares

Every source, with its share and the emission factor used in the carbon estimate.

delayed data · as of 01/11/2026, 12:15:00

Hard coal: 7310 MW Solar: 3784 MW Lignite: 3433 MW Natural gas: 2150 MW Other sources: 560 MW Biomass: 341 MW Onshore wind: 164 MW Oil: 161 MW 18,021 MW total
  • Hard coal 41% 7,310MW
    Renewable
    no
    Emission factor
    820 g CO₂eq/kWh
    Adds to the national average
    332.6 g/kWh
  • Solar 21% 3,784MW
    Renewable
    yes
    Emission factor
    45 g CO₂eq/kWh
    Adds to the national average
    9.4 g/kWh
  • Lignite 19% 3,433MW
    Renewable
    no
    Emission factor
    1,054 g CO₂eq/kWh
    Adds to the national average
    200.8 g/kWh
  • Natural gas 12% 2,150MW
    Renewable
    no
    Emission factor
    490 g CO₂eq/kWh
    Adds to the national average
    58.5 g/kWh
  • Other sources 3% 560MW
    Renewable
    no
    Emission factor
    490 g CO₂eq/kWh · weak factor, the figure is fragile
    Adds to the national average
    15.2 g/kWh
  • Biomass 2% 341MW
    Renewable
    yes
    Emission factor
    230 g CO₂eq/kWh · weak factor, the figure is fragile
    Adds to the national average
    4.4 g/kWh
  • Onshore wind 1% 164MW
    Renewable
    yes
    Emission factor
    11 g CO₂eq/kWh
    Adds to the national average
    0.1 g/kWh
  • Oil 1% 161MW
    Renewable
    no
    Emission factor
    650 g CO₂eq/kWh
    Adds to the national average
    5.8 g/kWh
  • Run-of-river hydro 0% 56MW
    Renewable
    yes
    Emission factor
    24 g CO₂eq/kWh
    Adds to the national average
    0.1 g/kWh
  • Offshore wind 0% 45MW
    Renewable
    yes
    Emission factor
    12 g CO₂eq/kWh
    Adds to the national average
    0.0 g/kWh
  • Hydro reservoir 0% 17MW
    Renewable
    yes
    Emission factor
    24 g CO₂eq/kWh
    Adds to the national average
    0.0 g/kWh

Renewable energy

Share of clean sources in total production.

delayed data · as of 01/11/2026, 12:15:00

Solar: 3784 MW · Biomass: 341 MW · Onshore wind: 164 MW · Run-of-river hydro: 56 MW · Offshore wind: 45 MW · Hydro reservoir: 17 MW 24,5% of production
  • Solar3,784 MW
  • Biomass341 MW
  • Onshore wind164 MW
  • Run-of-river hydro56 MW
  • Offshore wind45 MW
  • Hydro reservoir17 MW

Energy radar

delayed data · as of 01/11/2026, 12:15:00

2.686 5.371 8.057 10.743 Solar: 3784 MW Wind: 210 MW Hydro: 73 MW Nuclear: 0 MW Gas: 2311 MW Coal: 10743 MW Solar Wind Hydro Nuclear Gas Coal

Czechia 1.444 MW export Germany 702 MW import Slovakia 688 MW export Sweden 502 MW import Ukraine 396 MW export Lithuania 114 MW export POLAND cross-border energy flows THE NATIONAL POWER SYSTEM IN ITS REGIONAL CONNECTIONS Import into Poland (energy coming in) Export from Poland (energy going out) Total cross-border exchange 3.846 MW Import 1.203 MW Export 2.643 MW 0 50 100 200 km N

The arrows and figures are measurements, as of 1 November at 11:45. The transmission grid is not shown: we do not have its routes for this country yet.

Exchanges with neighbours

Green = Poland exports, orange = Poland imports.

delayed data · as of 01/11/2026, 12:15:00

Czechia Czechia: 1444 MW Germany Germany: 702 MW Slovakia Slovakia: 688 MW Sweden Sweden: 502 MW Ukraine Ukraine: 396 MW Lithuania Lithuania: 114 MW 0

The price right now, across Europe

The interval in progress, live data from right now, in every bidding zone we have a price for.

live data · as of 01/11/2026, 13:15:00

Poland is 38 of 46, counting from the dearest. Average across zones: 197 EUR/MWh.

  1. 1 MK 280EUR/MWh
  2. 2 RO 272EUR/MWh
  3. 3 BG 269EUR/MWh
  4. 3 GR 269EUR/MWh
  5. 5 IT (CALABRIA) 264EUR/MWh
  6. 5 IT (CENTRE_NORTH) 264EUR/MWh
  7. 5 IT (CENTRE_SOUTH) 264EUR/MWh
  8. 5 IT (NORTH) 264EUR/MWh
  9. 5 IT (SARDINIA) 264EUR/MWh
  10. 5 IT (SICILY) 264EUR/MWh
  11. 5 IT (SOUTH) 264EUR/MWh
  12. 12 HR 261EUR/MWh
  13. 12 SI 261EUR/MWh
  14. 14 AT 257EUR/MWh
  15. 15 RS 253EUR/MWh
  16. 16 SK 250EUR/MWh
  17. 17 CZ 249EUR/MWh
  18. 17 HU 249EUR/MWh
  19. 19 LT 248EUR/MWh
  20. 19 LV 248EUR/MWh
  21. 21 ME 245EUR/MWh
  22. 22 IE 244EUR/MWh
  23. 23 CH 240EUR/MWh
  24. 24 DE and LU 239EUR/MWh
  25. 24 DK (DK2) 239EUR/MWh
  26. 26 DK (DK1) 234EUR/MWh
  27. 26 AL 234EUR/MWh
  28. 26 XK 234EUR/MWh
  29. 29 SE (SE4) 229EUR/MWh
  30. 30 NL 212EUR/MWh
  31. 31 NO (NO2) 201EUR/MWh
  32. 32 NO (NO1) 189EUR/MWh
  33. 33 BE 188EUR/MWh
  34. 34 NO (NO5) 180EUR/MWh
  35. 35 EE 165EUR/MWh
  36. 36 SE (SE3) 137EUR/MWh
  37. 37 NO (NO3) 117EUR/MWh
  38. 38 PL 112EUR/MWh
  39. 39 TR 57EUR/MWh
  40. 40 FR 54EUR/MWh
  41. 41 SE (SE2) 25EUR/MWh
  42. 42 FI 24EUR/MWh
  43. 42 SE (SE1) 24EUR/MWh
  44. 44 NO (NO4) 20EUR/MWh
  45. 45 PT -0EUR/MWh
  46. 46 ES -4EUR/MWh

Wholesale prices for the interval covering this moment, bidding zone by bidding zone — countries with several zones appear once per zone, with its code in brackets. The average is arithmetic across zones, not weighted by demand: a small zone counts as much as a large one. The figures exclude network tariffs, excise duty and VAT.

What balancing cost, in the last 24 hours

The source for this country does not publish this dataset. Nothing is estimated in its place.

Who consumes: the base, the work rhythm, the day

An estimate from the shape of the consumption curve, not a measurement by customer category — that is not published in real time. Three parts: what never stops, what runs in shifts on working days, what switches on during the day.

archive up to 01/11/2026, 11:00:00

The base, non-stop
12,970MW
67.4% of the week's average · the Sunday-night floor: fridges, servers, installations that never stop
The work rhythm
2,078MW
10.8% of the week's average · how much more a working night carries than a Sunday night: the shifts
The day
4,207MW
21.9% of the week's average · what exceeds the working-night floor, on average: offices, shops, homes awake

Over the last seven days consumption averaged 19,255 MW and ranged between 13,166 and 23,154 MW.

How it was measured: the median of the 02–05 hours over 8 Sunday mornings (12,970 MW) and over 30 working mornings, Tuesday to Friday (15,047 MW), across the last 8 weeks; the average over the last seven days. The parts are cut from one another in order and add up exactly to the average.

The parts are shapes of the curve, not customer categories: the base holds every household's fridge as well as a plant that never stops; the day holds single-shift factories too. “Industrial” and “household” would be words these data cannot defend.

The operator's consumption forecast

How much the country is expected to consume, hour by hour, according to the forecast the transmission operator publishes for today and tomorrow. The line is the forecast; the bars, consumption measured so far.

forecast issued 01/11/2026, 12:40:57 · ENTSO-E

Operator's forecast Measured consumption, hourly average
0 12,500 25,000 37,500 50,000 00:00 — 14,195 MW 01:00 — 13,637 MW 02:00 — 13,262 MW 03:00 — 13,166 MW 04:00 — 13,205 MW 05:00 — 13,433 MW 06:00 — 13,721 MW 07:00 — 14,691 MW 08:00 — 15,589 MW 09:00 — 16,195 MW 10:00 — 16,208 MW 11:00 — 16,386 MW 12:00 — 16,137 MW today tomorrow now 00 06 12 18 00 06 12 18
Today's peak
18,100MW
at 19:30
Today's low
13,800MW
at 02:45
Next hour
16,150MW
at 13:30
Tomorrow's peak
23,550MW
at 13:00

The forecast is the transmission operator's, published on its own platform — not a model of ours. It is revised during the day; for each hour the latest issue is shown. The running hour, in the bars, only shows what has accumulated so far.

Units out of service

Unavailable capacity, now and over the next two weeks

4,273 MW out now

Unit Lost Period
BełchatówLignite · Bełchatów B14 781 MW 13 Jul – 11 Dec forced
Kozienice 2Hard coal · Kozienice 2 B10 534 MW 18 Sept – 17 Dec forced
EC Żerań 2Natural gas · EC Żerań BGP 484 MW 12 May – 15 Dec maintenance
Pątnów 2Lignite · Pątnów 2 B9 441 MW 18 Sept – 31 Dec forced
Pątnów 2Lignite · Pątnów 2 B9 441 MW 27 Sept – 31 Dec forced
ŁagiszaHard coal · Łagisza B10 430 MW 29 Sept – 1 Nov forced
BełchatówLignite · Bełchatów B07 357 MW 13 Sept – 10 Dec forced
TurówLignite · Turów B04 236 MW 31 Jul – 15 Nov forced
PołaniecHard coal · Połaniec B7 221 MW 11 Oct – 12 Nov forced
Jaworzno 3Hard coal · Jaworzno 3 B6 211 MW 30 Sept – 28 Dec forced

and 1 more

How much prosumers produce right now

The source for this country does not publish this dataset. Nothing is estimated in its place.

Today's solar, hour by hour

Measured hourly average for the current local day. The running hour only shows what has accumulated so far.

delayed data · as of 01/11/2026, 12:15:00

2363 4726 00:00 — 0 MW 01:00 — 0 MW 02:00 — 0 MW 03:00 — 0 MW 04:00 — 0 MW 05:00 — 0 MW 06:00 — 48 MW 07:00 — 640 MW 08:00 — 1840 MW 09:00 — 2970 MW 10:00 — 4094 MW 11:00 — 4726 MW 12:00 — 4032 MW 00 06 12 18 23

Today's wind, hour by hour

Measured hourly average for the current local day. The running hour only shows what has accumulated so far.

delayed data · as of 01/11/2026, 12:15:00

803 1605 00:00 — 1605 MW 01:00 — 1394 MW 02:00 — 1195 MW 03:00 — 1088 MW 04:00 — 962 MW 05:00 — 873 MW 06:00 — 768 MW 07:00 — 597 MW 08:00 — 340 MW 09:00 — 226 MW 10:00 — 175 MW 11:00 — 177 MW 12:00 — 200 MW 00 06 12 18 23

Today's storage, hour by hour

Deduced, not read from a key: the generation the feed includes in its total without itemising — by its behaviour, battery discharge. The bar is the hour's average, the dotted line the hour's peak power.

delayed data · as of 01/11/2026, 12:15:00

300 600 00:00 — 581 MW 01:00 — 582 MW 02:00 — 583 MW 03:00 — 588 MW 04:00 — 583 MW 05:00 — 588 MW 06:00 — 597 MW 07:00 — 599 MW 08:00 — 587 MW 09:00 — 584 MW 10:00 — 582 MW 11:00 — 581 MW 12:00 — 565 MW MW — vârf 00 06 12 18 23

The Transelectrica feed has no storage key. The figure is the difference between the published total and the named sources: constant at night, near zero by day — the behaviour of a discharging battery. It is a deduction labelled as such, not a measurement.

How we estimated 627 g CO₂/kWh

This is an estimate, not a measurement. There is no official carbon-intensity measurement for this country, so we compute it from the production mix.

Σ(source generation × source factor) / Σ(generation), over positive values, with life-cycle factors.

The factors are life-cycle values — they include construction and fuel, not just combustion. That is why solar, wind and nuclear are not zero. Source: IPCC AR5 WG3, Anexa III, Tabelul A.III.2 (mediane), version 1.

SourceMWg/kWh
Hard coal7,310820
Solar3,78445
Lignite3,4331054
Natural gas2,150490
Other sources560490
Biomass341230
Onshore wind16411
Oil161650
Run-of-river hydro5624
Offshore wind4512
Hydro reservoir1724

Energy news

See all the news

No announcement has appeared yet. When the first one does, you will find it here.

The generation fleet, 2026

Installed capacity by source, as the operator reports it.

Installed capacity 68,256MW reported for 2026 Cleaner energy for tomorrow
Renewables 48.2% 32,923 MW
Largest source Solar 30.4%
Against 2025 +3,753 MW
Source Capacity (MW) Of total
Solar 20,734+2,918 30.4%
Hard coal 18,543−1 27.2%
Onshore wind 10,700+400 15.7%
Lignite 6,951 10.2%
Natural gas 5,930+119 8.7%
Other sources 1,980+242 2.9%
Pumped-storage hydro 1,525 2.2%
Biomass 698+62 1.0%
Hydro reservoir 468 0.7%
Oil 405+13 0.6%
Run-of-river hydro 323+1 0.5%
All the capacity statistics
How the renewable share is computed

Σ(renewable sources, positive values only) / Σ(all sources, positive only).

Numerator: Solar, Biomass, Onshore wind, Run-of-river hydro, Offshore wind, Hydro reservoir.

Denominator: 18,021 MW.

Pumped-storage hydro and waste are not counted as renewable — the first would double-count energy, the second is partly fossil and its biogenic fraction cannot honestly be separated.

Consumption — 1 year

24 hours 48 hours 7 days 30 days 90 days 1 year all
15,00020,000 08/0609/1810/30

86 points, P1D resolution. Long ranges are served from precomputed aggregates — a one-year chart from per-minute data would push hundreds of thousands of points into the browser for nothing. Our archive starts at 2015-01-01 00:00 UTC.

By source

Each source has its own page, with history and context:

Solar power · Wind power · Hydropower · Power from natural gas · Power from coal · Power from biomass

Alerts

Get a browser notification when something you care about happens. The rules are evaluated locally, on the live stream — they work as long as a tab with the site is open. Email alerts arrive together with accounts, in a later phase.

Put this data on your site

Copy the snippet below. The widget updates itself and loads no JavaScript into your page.

<iframe src="https://euroenergy.live/widgets/country/poland?lang=en" width="100%" height="380" style="border:1px solid #dbe1ec;border-radius:16px;max-width:400px" loading="lazy" title="Poland — Electricity in real time"></iframe>

View the widget · Download CSV

Source: ENTSO-E Transparency Platform · shares are computed on positive values, because solar farms draw from the grid at night · JSON API: /api/v1/countries/PL/latest

Solar calculatorWhat it costs, and how long until it pays for itself.Panels, panels with a battery, or just a battery if you already have panels. The calculator uses the solar radiation where you live, your household's consumption and local energy prices to estimate the cost, the yearly saving and the payback period.Open the page →