Electricity · real time

Slovenia

delayed Electricity prices, interval by interval → Installed capacity →

Energy market

The price of electricity today

The day-ahead auction result, in Ljubljana time.

Interval by interval

Grid snapshot

Demand, generation and balance, updated every minute.

delayed data · as of 13/09/2026, 06:15:00

National consumption
1,019MW
▼ −302 MW vs a day ago
Domestic production
1,228MW
Covers all national consumption; the 208 MW surplus (20.4%) goes to export.
▼ −391 MW vs a day ago
Exporting now
243MW
Measured on the interconnectors: 19.8% of current production flows to neighbours.
▲ +1,103 MW vs a day ago
Solar production
47MW
3.8% of current production.
▼ −95 MW vs a day ago
Nuclear now
699MW
56.9% of production, baseload.
Day-ahead price
205.9EUR/MWh
CO₂ estimated
34g/kWh
estimated

Physical cross-border flows

Electricity measured crossing every border in August 2026, valued at this zone's day-ahead price.

Physical exports 909,235 MWh estimated market value 131,924,489 €, at 145.09 €/MWh
Physical imports 791,355 MWh estimated market value 117,725,402 €, at 148.76 €/MWh
Estimated market value 14,199,088 the month averaged 152.09 €/MWh
Border with Out, MWh at €/MWh In, MWh at €/MWh Difference €
Italy 562,166 135.83 19,732 153.49 73,329,533
Austria 54,668 127.88 489,523 159.71 −71,192,740
Croatia 277,652 162.05 119,989 134.85 28,812,159
Hungary 14,749 242.88 162,110 125.42 −16,749,864

14,199,088 € for 117,880 MWh that stayed in the country works out at 120.45 € per megawatt-hour, in a month that averaged 152.09.

  • Energy that stayed, at the month's average price −17,928,081 126.3%
  • What came in arrived above that average −2,629,637 18.5%
  • What went out left below it 6,358,630 -44.8%

The first line is energy the country needed and got. The other two — 3,728,994 € together — come not from how much moved but from when: cheap hours to sell in, expensive hours to buy in. That is the price of a timing mismatch, not a loss.

Official validation AWAITING OFFICIAL ANRE DATA

Physical cross-border flows and commercial electricity trades measure different phenomena. ANRE data is shown as an independent official benchmark and should not be interpreted as an exact reconciliation.

All months, every border

Not an invoice. Cross-border electricity is not sold country to country: the markets are coupled and the physical flow is the outcome of a shared auction. These figures value the measured flow at this zone's own day-ahead price, so both directions can be compared on the same scale.

Flows are measured, quarter-hour by quarter-hour; hourly borders are spread across the four quarters they cover, so every megawatt-hour meets the price that was actually in force. Energy entering the country is not the same as energy consumed here — some of it passes through.

Who we sold energy to

Who we sold energy to when they needed it — last 30 days

data for the last 30 days · 29 days covered

  • Italy 703.78 GWh
    574 MW on average · 72.2%
  • Croatia 213.84 GWh
    472 MW on average · 21.9%
  • Austria 50.29 GWh
    404 MW on average · 5.2%
  • Hungary 6.54 GWh
    82 MW on average · 0.7%

What we sent our neighbours, per border. Energy summed from quarter-hour averages over the days actually covered by the archive. The average power is over the hours in which it flowed this way, not over every hour. A country can appear in both lists: with the same neighbour we import in some hours and export in others.

Who we bought energy from

Who sold us energy when we needed it — last 30 days

data for the last 30 days · 29 days covered

  • Austria 451.23 GWh
    810 MW on average · 57.8%
  • Hungary 185.68 GWh
    309 MW on average · 23.8%
  • Croatia 124.47 GWh
    545 MW on average · 16.0%
  • Italy 18.93 GWh
    153 MW on average · 2.4%

What our neighbours sent us, per border. Energy summed from quarter-hour averages over the days actually covered by the archive. The average power is over the hours in which it flowed this way, not over every hour. A country can appear in both lists: with the same neighbour we import in some hours and export in others.

Energy sources

delayed data · as of 13/09/2026, 06:15:00

Nuclear
699MW
56.9% of total
Run-of-river hydro
432MW
35.1% of total
Solar
47MW
3.8% of total
Natural gas
34MW
2.8% of total
Biomass
15MW
1.2% of total
Other sources
2MW
0.1% of total
Pumped-storage hydro
0MW
0.0% of total
Lignite
0MW
0.0% of total
Oil
0MW
0.0% of total
Waste
0MW
0.0% of total
Onshore wind
0MW
0.0% of total

Source shares

Every source, with its share and the emission factor used in the carbon estimate.

delayed data · as of 13/09/2026, 06:15:00

Nuclear: 699 MW Run-of-river hydro: 432 MW Solar: 47 MW Natural gas: 34 MW Biomass: 15 MW 1,228 MW total
  • Nuclear 699MW 56.9%
    details
    Renewable
    no
    Emission factor
    12 g CO₂eq/kWh
    Adds to the national average
    6.8 g/kWh
  • Run-of-river hydro 432MW 35.1%
    details
    Renewable
    yes
    Emission factor
    24 g CO₂eq/kWh
    Adds to the national average
    8.4 g/kWh
  • Solar 47MW 3.8%
    details
    Renewable
    yes
    Emission factor
    45 g CO₂eq/kWh
    Adds to the national average
    1.7 g/kWh
  • Natural gas 34MW 2.8%
    details
    Renewable
    no
    Emission factor
    490 g CO₂eq/kWh
    Adds to the national average
    13.6 g/kWh
  • Biomass 15MW 1.2%
    details
    Renewable
    yes
    Emission factor
    230 g CO₂eq/kWh · weak factor, the figure is fragile
    Adds to the national average
    2.8 g/kWh
  • Other sources 2MW 0.1%
    details
    Renewable
    no
    Emission factor
    490 g CO₂eq/kWh · weak factor, the figure is fragile
    Adds to the national average
    0.7 g/kWh

Renewable energy

Share of clean sources in total production.

delayed data · as of 13/09/2026, 06:15:00

Run-of-river hydro: 432 MW Solar: 47 MW Biomass: 15 MW 40,2% of production
Run-of-river hydro 432 MW Solar 47 MW Biomass 15 MW

Energy radar

delayed data · as of 13/09/2026, 06:15:00

Solar: 47 MW Wind: 0 MW Hydro: 432 MW Nuclear: 699 MW Gas: 34 MW Coal: 0 MW Solar Wind Hydro Nuclear Gas Coal

Italy 988 MW export Croatia 817 MW import Austria 382 MW export Hungary 310 MW import SLOVENIA cross-border energy flows THE NATIONAL POWER SYSTEM IN ITS REGIONAL CONNECTIONS Import into Slovenia (energy coming in) Export from Slovenia (energy going out) Total cross-border exchange 2.496 MW Import 1.127 MW Export 1.370 MW 0 50 100 200 km N

The arrows and figures are measurements, as of 13 September at 04:45. The transmission grid is not shown: we do not have its routes for this country yet.

Exchanges with neighbours

Green = Slovenia exports, orange = Slovenia imports.

delayed data · as of 13/09/2026, 06:15:00

Italy Italy: 988 MW Croatia Croatia: 817 MW Austria Austria: 382 MW Hungary Hungary: 310 MW 0

The price right now, across Europe

The interval in progress, live data from right now, in every bidding zone we have a price for.

live data · as of 13/09/2026, 07:15:00

Slovenia is 10 of 38, counting from the dearest. Average across zones: 137 EUR/MWh.

  1. IT (CALABRIA) 227EUR/MWh
  2. IT (CENTRE_NORTH) 227EUR/MWh
  3. IT (CENTRE_SOUTH) 227EUR/MWh
  4. IT (NORTH) 227EUR/MWh
  5. IT (SARDINIA) 227EUR/MWh
  6. IT (SICILY) 227EUR/MWh
  7. IT (SOUTH) 227EUR/MWh
  8. IE 217EUR/MWh
  9. AT 214EUR/MWh
  10. SI 206EUR/MWh
  11. BG 197EUR/MWh
  12. ES 194EUR/MWh
  13. PT 189EUR/MWh
  14. FR 186EUR/MWh
  15. BE 184EUR/MWh
  16. DK (DK1) 180EUR/MWh
  17. DK (DK2) 179EUR/MWh
  18. NO (NO2) 172EUR/MWh
  19. AL 169EUR/MWh
  20. XK 169EUR/MWh
  21. CH 158EUR/MWh
  22. PL 148EUR/MWh
  23. NO (NO5) 145EUR/MWh
  24. CZ 141EUR/MWh
  25. NO (NO1) 138EUR/MWh
  26. RS 130EUR/MWh
  27. ME 127EUR/MWh
  28. NO (NO3) 88EUR/MWh
  29. TR 21EUR/MWh
  30. EE 14EUR/MWh
  31. LT 14EUR/MWh
  32. LV 14EUR/MWh
  33. SE (SE4) 11EUR/MWh
  34. SE (SE3) 10EUR/MWh
  35. SE (SE2) 7EUR/MWh
  36. FI 6EUR/MWh
  37. SE (SE1) 6EUR/MWh
  38. NO (NO4) 1EUR/MWh

Wholesale prices for the interval covering this moment, bidding zone by bidding zone — countries with several zones appear once per zone, with its code in brackets. The average is arithmetic across zones, not weighted by demand: a small zone counts as much as a large one. The figures exclude network tariffs, excise duty and VAT.

What balancing cost, in the last 24 hours

The source for this country does not publish this dataset. Nothing is estimated in its place.

Who consumes: the base, the work rhythm, the day

An estimate from the shape of the consumption curve, not a measurement by customer category — that is not published in real time. Three parts: what never stops, what runs in shifts on working days, what switches on during the day.

archive up to 13/09/2026, 04:00:00

The base, non-stop
939MW
62.0% of the week's average · the Sunday-night floor: fridges, servers, installations that never stop
The work rhythm
177MW
11.7% of the week's average · how much more a working night carries than a Sunday night: the shifts
The day
399MW
26.3% of the week's average · what exceeds the working-night floor, on average: offices, shops, homes awake

Over the last seven days consumption averaged 1,514 MW and ranged between 953 and 2,199 MW.

How it was measured: the median of the 02–05 hours over 8 Sunday mornings (939 MW) and over 30 working mornings, Tuesday to Friday (1,116 MW), across the last 8 weeks; the average over the last seven days. The parts are cut from one another in order and add up exactly to the average.

The parts are shapes of the curve, not customer categories: the base holds every household's fridge as well as a plant that never stops; the day holds single-shift factories too. “Industrial” and “household” would be words these data cannot defend.

The operator's consumption forecast

How much the country is expected to consume, hour by hour, according to the forecast the transmission operator publishes for today and tomorrow. The line is the forecast; the bars, consumption measured so far.

forecast issued 13/09/2026, 07:22:04 · ENTSO-E

Operator's forecast Measured consumption, hourly average
0 500 1,000 1,500 2,000 00:00 — 1,034 MW 01:00 — 1,001 MW 02:00 — 975 MW 03:00 — 959 MW 04:00 — 953 MW 05:00 — 934 MW 06:00 — 995 MW today tomorrow now 00 06 12 18 00 06 12 18
Today's peak
1,327MW
at 10:45
Today's low
990MW
at 02:30
Next hour
1,165MW
at 07:30
Tomorrow's peak
Tomorrow's forecast is not published yet.

The forecast is the transmission operator's, published on its own platform — not a model of ours. It is revised during the day; for each hour the latest issue is shown. The running hour, in the bars, only shows what has accumulated so far.

Units out of service

Unavailable capacity, now and over the next two weeks

1,078 MW out now

Unit Lost Period
TE ŠoštanjLignite 539 MW 31 Jul – 12 Oct maintenance
TE ŠoštanjLignite 539 MW 31 Jul – 12 Oct forced
ČHE Avče elektrarnaPumped-storage hydro 180 MW 23 Sept – 4 Oct announced

How much prosumers produce right now

The source for this country does not publish this dataset. Nothing is estimated in its place.

Today's solar, hour by hour

Measured hourly average for the current local day. The running hour only shows what has accumulated so far.

delayed data · as of 13/09/2026, 06:15:00

25 51 00:00 — 1 MW 01:00 — 1 MW 02:00 — 1 MW 03:00 — 1 MW 04:00 — 1 MW 05:00 — 7 MW 06:00 — 51 MW 00 06 12 18 23

Today's wind, hour by hour

Measured hourly average for the current local day. The running hour only shows what has accumulated so far.

delayed data · as of 13/09/2026, 06:15:00

1 1 00:00 — 1 MW 01:00 — 1 MW 02:00 — 1 MW 03:00 — 0 MW 04:00 — 0 MW 05:00 — 0 MW 06:00 — 0 MW 00 06 12 18 23

Today's storage, hour by hour

Deduced, not read from a key: the generation the feed includes in its total without itemising — by its behaviour, battery discharge. The bar is the hour's average, the dotted line the hour's peak power.

delayed data · as of 13/09/2026, 06:15:00

1 2 00:00 — 2 MW 01:00 — 2 MW 02:00 — 2 MW 03:00 — 2 MW 04:00 — 2 MW 05:00 — 2 MW 06:00 — 2 MW MW — vârf 00 06 12 18 23

The Transelectrica feed has no storage key. The figure is the difference between the published total and the named sources: constant at night, near zero by day — the behaviour of a discharging battery. It is a deduction labelled as such, not a measurement.

How we estimated 34 g CO₂/kWh

This is an estimate, not a measurement. There is no official carbon-intensity measurement for this country, so we compute it from the production mix.

Σ(source generation × source factor) / Σ(generation), over positive values, with life-cycle factors.

The factors are life-cycle values — they include construction and fuel, not just combustion. That is why solar, wind and nuclear are not zero. Source: IPCC AR5 WG3, Anexa III, Tabelul A.III.2 (mediane), version 1.

SourceMWg/kWh
Nuclear69912
Run-of-river hydro43224
Solar4745
Natural gas34490
Biomass15230
Other sources2490

The generation fleet, 2026

Installed capacity by source, as the operator reports it.

Installed capacity 5,346MW reported for 2026 Cleaner energy for tomorrow
Renewables 51.3% 2,741 MW
Largest source Solar 29.5%
Against 2025 −146 MW
Source Capacity (MW) Of total
Solar 1,577+165 29.5%
Run-of-river hydro 1,113−32 20.8%
Lignite 894−296 16.7%
Natural gas 765+1 14.3%
Nuclear 700 13.1%
Pumped-storage hydro 180 3.4%
Oil 58 1.1%
Biomass 47+14 0.9%
Waste 8+2 0.1%
Onshore wind 4+1 0.1%
All the capacity statistics
How the renewable share is computed

Σ(renewable sources, positive values only) / Σ(all sources, positive only).

Numerator: Run-of-river hydro, Solar, Biomass, Onshore wind.

Denominator: 1,228 MW.

Pumped-storage hydro and waste are not counted as renewable — the first would double-count energy, the second is partly fossil and its biogenic fraction cannot honestly be separated.

Consumption — 1 year

24 hours 48 hours 7 days 30 days 90 days 1 year all
1,2001,4001,6001,800 08/0608/2409/11

37 points, P1D resolution. Long ranges are served from precomputed aggregates — a one-year chart from per-minute data would push hundreds of thousands of points into the browser for nothing. Our archive starts at 2015-01-01 00:00 UTC.

By source

Each source has its own page, with history and context:

Solar power · Wind power · Hydropower · Nuclear power · Power from natural gas · Power from coal · Power from biomass

Alerts

Get a browser notification when something you care about happens. The rules are evaluated locally, on the live stream — they work as long as a tab with the site is open. Email alerts arrive together with accounts, in a later phase.

Put this data on your site

Copy the snippet below. The widget updates itself and loads no JavaScript into your page.

<iframe src="https://euroenergy.live/widgets/country/slovenia?lang=en" width="100%" height="370" style="border:1px solid #dbe1ec;border-radius:12px;max-width:640px" loading="lazy" title="Slovenia — Electricity in real time"></iframe>

View the widget · Download CSV

Source: ENTSO-E Transparency Platform · shares are computed on positive values, because solar farms draw from the grid at night · JSON API: /api/v1/countries/SI/latest