local timeUTC+1
Electricity · real time

Slovakia

delayed Electricity prices, interval by interval →

Energy market

The price of electricity today

The day-ahead auction result, in Bratislava time.

Interval by interval

Grid snapshot

Demand, generation and balance, updated every minute.

delayed data · as of 05/11/2026, 16:45:00

National consumption
3,670MW
▲ +24 MW vs a day ago
Domestic production
3,543MW
128 MW below consumption. The real border balance is measured separately.
▲ +17 MW vs a day ago
Importing now
34MW
Measured on the interconnectors, 0.9% of consumption. The 128 MW difference from “consumption minus production” is expected: generation-by-source as published does not cover everything that is generated.
▼ −2,257 MW vs a day ago
Solar production
2MW
unchanged vs a day ago
Nuclear now
1,956MW
55.2% of production, baseload.
Day-ahead price
383.1EUR/MWh
CO₂ estimated
137g/kWhestimated

Physical cross-border flows

Electricity measured crossing every border in October 2026, valued at this zone's day-ahead price.

Physical exports 1,310,953 MWh estimated market value 294,743,713 €, at 224.83 €/MWh
Physical imports 1,521,769 MWh estimated market value 333,766,507 €, at 219.33 €/MWh
Estimated market value −39,022,794 € the month averaged 219.06 €/MWh
Border with Out, MWh at €/MWh In, MWh at €/MWh Difference €
Hungary 1,291,054 226.80 19,173 73.38 291,409,282
Czechia 17,909 76.09 1,155,577 227.88 −261,969,480
Poland 1,990 283.85 347,020 198.92 −68,462,596

39,022,794 € for 210,816 MWh that stayed in the country works out at 185.10 € per megawatt-hour, in a month that averaged 219.06.

  • Energy that stayed, at the month's average price 46,180,939 118.3%
  • What came in arrived above that average 411,217 1.1%
  • What went out left below it −7,569,362 -19.4%

The first line is energy the country needed and got. The other two — 7,158,145 € together — come not from how much moved but from when: cheap hours to sell in, expensive hours to buy in. That is the price of a timing mismatch, not a loss.

Official validation AWAITING OFFICIAL ANRE DATA

Physical cross-border flows and commercial electricity trades measure different phenomena. ANRE data is shown as an independent official benchmark and should not be interpreted as an exact reconciliation.

All months, every border

Not an invoice. Cross-border electricity is not sold country to country: the markets are coupled and the physical flow is the outcome of a shared auction. These figures value the measured flow at this zone's own day-ahead price, so both directions can be compared on the same scale.

Flows are measured, quarter-hour by quarter-hour; hourly borders are spread across the four quarters they cover, so every megawatt-hour meets the price that was actually in force. Energy entering the country is not the same as energy consumed here — some of it passes through.

Who we sold energy to

Who we sold energy to when they needed it — last 30 days

data for the last 30 days · 30 days covered

  • Hungary 1,296.27 GWh
    1,812 MW on average · 98.5%
  • Ukraine 19.13 GWh
    638 MW on average · 1.5%
  • Poland 0.93 GWh
    59 MW on average · 0.1%
  • Czechia 0.25 GWh
    113 MW on average · 0.0%

What we sent our neighbours, per border. Energy summed from quarter-hour averages over the days actually covered by the archive. The average power is over the hours in which it flowed this way, not over every hour. A country can appear in both lists: with the same neighbour we import in some hours and export in others.

Who we bought energy from

Who sold us energy when we needed it — last 30 days

data for the last 30 days · 30 days covered

  • Czechia 1,164.30 GWh
    1,622 MW on average · 77.4%
  • Poland 338.07 GWh
    482 MW on average · 22.5%
  • Hungary 1.07 GWh
    224 MW on average · 0.1%

What our neighbours sent us, per border. Energy summed from quarter-hour averages over the days actually covered by the archive. The average power is over the hours in which it flowed this way, not over every hour. A country can appear in both lists: with the same neighbour we import in some hours and export in others.

Energy sources

delayed data · as of 05/11/2026, 16:45:00

Nuclear
1,956MW
55.2% of total
Natural gas
603MW
17.0% of total
Pumped-storage hydro
341MW
9.6% of total
Run-of-river hydro
227MW
6.4% of total
Other sources
179MW
5.1% of total
Biomass
109MW
3.1% of total
Hydro reservoir
60MW
1.7% of total
Oil
53MW
1.5% of total
Lignite
12MW
0.3% of total
Solar
2MW
0.1% of total
Hard coal
0MW
0.0% of total
Onshore wind
0MW
0.0% of total

Source shares

Every source, with its share and the emission factor used in the carbon estimate.

delayed data · as of 05/11/2026, 16:45:00

Nuclear: 1956 MW Natural gas: 603 MW Pumped-storage hydro: 341 MW Run-of-river hydro: 227 MW Other sources: 179 MW Biomass: 109 MW Hydro reservoir: 60 MW Oil: 53 MW 3,543 MW total
  • Nuclear 55% 1,956MW
    Renewable
    no
    Emission factor
    12 g CO₂eq/kWh
    Adds to the national average
    6.6 g/kWh
  • Natural gas 17% 603MW
    Renewable
    no
    Emission factor
    490 g CO₂eq/kWh
    Adds to the national average
    83.4 g/kWh
  • Pumped-storage hydro 10% 341MW
    Renewable
    no — storage, not generation: the energy was counted once, when the water was pumped
    Emission factor
    0 g CO₂eq/kWh
    Adds to the national average
    0.0 g/kWh
  • Run-of-river hydro 6% 227MW
    Renewable
    yes
    Emission factor
    24 g CO₂eq/kWh
    Adds to the national average
    1.5 g/kWh
  • Other sources 5% 179MW
    Renewable
    no
    Emission factor
    490 g CO₂eq/kWh · weak factor, the figure is fragile
    Adds to the national average
    24.8 g/kWh
  • Biomass 3% 109MW
    Renewable
    yes
    Emission factor
    230 g CO₂eq/kWh · weak factor, the figure is fragile
    Adds to the national average
    7.1 g/kWh
  • Hydro reservoir 2% 60MW
    Renewable
    yes
    Emission factor
    24 g CO₂eq/kWh
    Adds to the national average
    0.4 g/kWh
  • Oil 1% 53MW
    Renewable
    no
    Emission factor
    650 g CO₂eq/kWh
    Adds to the national average
    9.7 g/kWh
  • Lignite 0% 12MW
    Renewable
    no
    Emission factor
    1,054 g CO₂eq/kWh
    Adds to the national average
    3.7 g/kWh
  • Solar 0% 2MW
    Renewable
    yes
    Emission factor
    45 g CO₂eq/kWh
    Adds to the national average
    0.0 g/kWh

Renewable energy

Share of clean sources in total production.

delayed data · as of 05/11/2026, 16:45:00

Run-of-river hydro: 227 MW · Biomass: 109 MW · Hydro reservoir: 60 MW · Solar: 2 MW 11,2% of production
  • Run-of-river hydro227 MW
  • Biomass109 MW
  • Hydro reservoir60 MW
  • Solar2 MW

Energy radar

delayed data · as of 05/11/2026, 16:45:00

489 978 1.467 1.956 Solar: 2 MW Wind: 0 MW Hydro: 628 MW Nuclear: 1956 MW Gas: 656 MW Coal: 12 MW Solar Wind Hydro Nuclear Gas Coal

Czechia 1.920 MW import Hungary 1.755 MW export Ukraine 662 MW export Poland 532 MW import SLOVAKIA cross-border energy flows THE NATIONAL POWER SYSTEM IN ITS REGIONAL CONNECTIONS Import into Slovakia (energy coming in) Export from Slovakia (energy going out) Total cross-border exchange 4.869 MW Import 2.452 MW Export 2.418 MW 0 50 100 200 km N

The arrows and figures are measurements, as of 5 November at 17:00. The transmission grid is not shown: we do not have its routes for this country yet.

Exchanges with neighbours

Green = Slovakia exports, orange = Slovakia imports.

delayed data · as of 05/11/2026, 16:45:00

Czechia Czechia: 1920 MW Hungary Hungary: 1755 MW Ukraine Ukraine: 662 MW Poland Poland: 532 MW 0

The price right now, across Europe

The interval in progress, live data from right now, in every bidding zone we have a price for.

live data · as of 05/11/2026, 18:30:00

Slovakia is 6 of 46, counting from the dearest. Average across zones: 301 EUR/MWh.

  1. 1 AL 651EUR/MWh
  2. 1 XK 651EUR/MWh
  3. 3 IE 555EUR/MWh
  4. 4 RS 401EUR/MWh
  5. 5 ME 400EUR/MWh
  6. 6 SK 383EUR/MWh
  7. 7 MK 380EUR/MWh
  8. 8 HU 373EUR/MWh
  9. 9 RO 370EUR/MWh
  10. 10 HR 365EUR/MWh
  11. 11 SI 362EUR/MWh
  12. 12 BG 358EUR/MWh
  13. 12 GR 358EUR/MWh
  14. 14 AT 357EUR/MWh
  15. 15 PL 354EUR/MWh
  16. 16 DK (DK2) 351EUR/MWh
  17. 17 FR 350EUR/MWh
  18. 17 IT (CALABRIA) 350EUR/MWh
  19. 17 IT (CENTRE_NORTH) 350EUR/MWh
  20. 17 IT (CENTRE_SOUTH) 350EUR/MWh
  21. 17 IT (NORTH) 350EUR/MWh
  22. 17 IT (SARDINIA) 350EUR/MWh
  23. 17 IT (SICILY) 350EUR/MWh
  24. 17 IT (SOUTH) 350EUR/MWh
  25. 25 BE 349EUR/MWh
  26. 25 NL 349EUR/MWh
  27. 27 DE and LU 348EUR/MWh
  28. 27 DK (DK1) 348EUR/MWh
  29. 29 CZ 344EUR/MWh
  30. 30 CH 334EUR/MWh
  31. 31 PT 321EUR/MWh
  32. 32 SE (SE4) 311EUR/MWh
  33. 33 ES 305EUR/MWh
  34. 34 NO (NO2) 250EUR/MWh
  35. 35 NO (NO5) 235EUR/MWh
  36. 36 NO (NO1) 231EUR/MWh
  37. 37 SE (SE3) 148EUR/MWh
  38. 38 NO (NO3) 120EUR/MWh
  39. 39 EE 105EUR/MWh
  40. 39 LT 105EUR/MWh
  41. 39 LV 105EUR/MWh
  42. 42 TR 56EUR/MWh
  43. 43 NO (NO4) 17EUR/MWh
  44. 44 SE (SE1) 6EUR/MWh
  45. 44 FI 6EUR/MWh
  46. 46 SE (SE2) 3EUR/MWh

Wholesale prices for the interval covering this moment, bidding zone by bidding zone — countries with several zones appear once per zone, with its code in brackets. The average is arithmetic across zones, not weighted by demand: a small zone counts as much as a large one. The figures exclude network tariffs, excise duty and VAT.

What balancing cost, in the last 24 hours

The source for this country does not publish this dataset. Nothing is estimated in its place.

Who consumes: the base, the work rhythm, the day

An estimate from the shape of the consumption curve, not a measurement by customer category — that is not published in real time. Three parts: what never stops, what runs in shifts on working days, what switches on during the day.

archive up to 05/11/2026, 16:00:00

The base, non-stop
2,166MW
69.4% of the week's average · the Sunday-night floor: fridges, servers, installations that never stop
The work rhythm
275MW
8.8% of the week's average · how much more a working night carries than a Sunday night: the shifts
The day
679MW
21.8% of the week's average · what exceeds the working-night floor, on average: offices, shops, homes awake

Over the last seven days consumption averaged 3,120 MW and ranged between 2,382 and 3,717 MW.

How it was measured: the median of the 02–05 hours over 8 Sunday mornings (2,166 MW) and over 32 working mornings, Tuesday to Friday (2,441 MW), across the last 8 weeks; the average over the last seven days. The parts are cut from one another in order and add up exactly to the average.

The parts are shapes of the curve, not customer categories: the base holds every household's fridge as well as a plant that never stops; the day holds single-shift factories too. “Industrial” and “household” would be words these data cannot defend.

The operator's consumption forecast

How much the country is expected to consume, hour by hour, according to the forecast the transmission operator publishes for today and tomorrow. The line is the forecast; the bars, consumption measured so far.

forecast issued 05/11/2026, 18:33:42 · ENTSO-E

Operator's forecast Measured consumption, hourly average
0 1,250 2,500 3,750 5,000 00:00 — 2,871 MW 01:00 — 2,810 MW 02:00 — 2,825 MW 03:00 — 2,811 MW 04:00 — 2,870 MW 05:00 — 3,075 MW 06:00 — 3,435 MW 07:00 — 3,597 MW 08:00 — 3,563 MW 09:00 — 3,491 MW 10:00 — 3,280 MW 11:00 — 3,275 MW 12:00 — 3,264 MW 13:00 — 3,246 MW 14:00 — 3,299 MW 15:00 — 3,384 MW 16:00 — 3,620 MW 17:00 — 3,670 MW today tomorrow now 00 06 12 18 00 06 12 18
Today's peak
3,710MW
at 17:15
Today's low
2,730MW
at 01:45
Next hour
3,660MW
at 18:45
Tomorrow's peak
3,664MW
at 17:30

The forecast is the transmission operator's, published on its own platform — not a model of ours. It is revised during the day; for each hour the latest issue is shown. The running hour, in the bars, only shows what has accumulated so far.

Units out of service

Unavailable capacity, now and over the next two weeks

470 MW out now

Unit Lost Period
MochovceNuclear · Mochovce TG22 235 MW 12 Sept – 9 Nov forced
MochovceNuclear · Mochovce TG21 235 MW 12 Sept – 9 Nov forced

How much prosumers produce right now

The source for this country does not publish this dataset. Nothing is estimated in its place.

Today's solar, hour by hour

Measured hourly average for the current local day. The running hour only shows what has accumulated so far.

delayed data · as of 05/11/2026, 16:45:00

155 311 00:00 — 0 MW 01:00 — 0 MW 02:00 — 0 MW 03:00 — 0 MW 04:00 — 0 MW 05:00 — 1 MW 06:00 — 3 MW 07:00 — 45 MW 08:00 — 141 MW 09:00 — 218 MW 10:00 — 282 MW 11:00 — 311 MW 12:00 — 297 MW 13:00 — 247 MW 14:00 — 160 MW 15:00 — 48 MW 16:00 — 3 MW 00 06 12 18 23

Today's wind, hour by hour

Measured hourly average for the current local day. The running hour only shows what has accumulated so far.

delayed data · as of 05/11/2026, 16:45:00

1 1 00:00 — 0 MW 01:00 — 1 MW 02:00 — 1 MW 03:00 — 0 MW 04:00 — 0 MW 05:00 — 0 MW 06:00 — 0 MW 07:00 — 0 MW 08:00 — 0 MW 09:00 — 0 MW 10:00 — 0 MW 11:00 — 0 MW 12:00 — 0 MW 13:00 — 0 MW 14:00 — 0 MW 15:00 — 0 MW 16:00 — 0 MW 00 06 12 18 23

Today's storage, hour by hour

Deduced, not read from a key: the generation the feed includes in its total without itemising — by its behaviour, battery discharge. The bar is the hour's average, the dotted line the hour's peak power.

delayed data · as of 05/11/2026, 16:45:00

101 201 00:00 — 170 MW 01:00 — 171 MW 02:00 — 174 MW 03:00 — 172 MW 04:00 — 188 MW 05:00 — 189 MW 06:00 — 198 MW 07:00 — 193 MW 08:00 — 186 MW 09:00 — 179 MW 10:00 — 178 MW 11:00 — 173 MW 12:00 — 171 MW 13:00 — 170 MW 14:00 — 176 MW 15:00 — 188 MW 16:00 — 184 MW MW — vârf 00 06 12 18 23

The Transelectrica feed has no storage key. The figure is the difference between the published total and the named sources: constant at night, near zero by day — the behaviour of a discharging battery. It is a deduction labelled as such, not a measurement.

How we estimated 137 g CO₂/kWh

This is an estimate, not a measurement. There is no official carbon-intensity measurement for this country, so we compute it from the production mix.

Σ(source generation × source factor) / Σ(generation), over positive values, with life-cycle factors.

The factors are life-cycle values — they include construction and fuel, not just combustion. That is why solar, wind and nuclear are not zero. Source: IPCC AR5 WG3, Anexa III, Tabelul A.III.2 (mediane), version 1.

SourceMWg/kWh
Nuclear1,95612
Natural gas603490
Pumped-storage hydro3410
Run-of-river hydro22724
Other sources179490
Biomass109230
Hydro reservoir6024
Oil53650
Lignite121054
Solar245

Energy news

See all the news

Installed capacity

The source for this country does not publish this dataset. Nothing is estimated in its place.

How the renewable share is computed

Σ(renewable sources, positive values only) / Σ(all sources, positive only).

Numerator: Run-of-river hydro, Biomass, Hydro reservoir, Solar, Onshore wind.

Denominator: 3,543 MW.

Pumped-storage hydro and waste are not counted as renewable — the first would double-count energy, the second is partly fossil and its biogenic fraction cannot honestly be separated.

Consumption — 1 year

24 hours 48 hours 7 days 30 days 90 days 1 year all
2,5003,000 08/0609/2011/03

90 points, P1D resolution. Long ranges are served from precomputed aggregates — a one-year chart from per-minute data would push hundreds of thousands of points into the browser for nothing. Our archive starts at 2015-01-01 00:00 UTC.

By source

Each source has its own page, with history and context:

Solar power · Wind power · Hydropower · Nuclear power · Power from natural gas · Power from coal · Power from biomass

Alerts

Get a browser notification when something you care about happens. The rules are evaluated locally, on the live stream — they work as long as a tab with the site is open. Email alerts arrive together with accounts, in a later phase.

Put this data on your site

Copy the snippet below. The widget updates itself and loads no JavaScript into your page.

<iframe src="https://euroenergy.live/widgets/country/slovakia?lang=en" width="100%" height="380" style="border:1px solid #dbe1ec;border-radius:16px;max-width:400px" loading="lazy" title="Slovakia — Electricity in real time"></iframe>

View the widget · Download CSV

Source: ENTSO-E Transparency Platform · shares are computed on positive values, because solar farms draw from the grid at night · JSON API: /api/v1/countries/SK/latest

Solar calculatorWhat it costs, and how long until it pays for itself.Panels, panels with a battery, or just a battery if you already have panels. The calculator uses the solar radiation where you live, your household's consumption and local energy prices to estimate the cost, the yearly saving and the payback period.Open the page